FKQ1800-14 - Oilfield Drilling Equipment Supply & Solutions

FKQ1800-14

 

NO. NAME Parameter
1.1 Working pressure 21 MPa (3000psi)
1.2 Controlled object quantity one ring style, two half sealed style, one sealed style, one discharge nozzle, one standby
1.3 Remote control console (sundries house in the corrugated iron house with interlayer) 12000mm(L)×3000mm(W)×2610mm(H)
Weight:14t
1.4 oil tank effective volume 2000L(528gal)
1.5 electric pump output, pressure, dynamo power 42L(11gal)/min×2、21MPa (3000psi)、18.5KW
1.6 gas-operated pump output × pressure× quantity 8L(2.1gal)/This email address is being protected from spambots. You need JavaScript enabled to view it.(1500psi)×3
1.7 gas-operated pump air source pressure (maxim air consumption) 0.53 ~0.8MPa(77~116psi) (4.5m3/min)
1.8 accumulator volume and structure 80L(21gal)×16,distribute bisymmetrically
1.9 accumulator nitrogen charging pressure 7±0.7 MPa(1015±102psi)
1.1 ram- type preventer control main fold manual pressure reducing overflow valve 0~14 MPa(2000psi),by pass valve start 21 MPa(3000psi)
1.11 ring preventer control main fold 0~18 MPa(2610psi)
1.12 electric pump automatic switch control <18.9 MPa(2700psi)Start、21 MPa(3000psi)Stop
1.13 gas-operated pump automatic switch control <18 MPa(2600psi) Start、21 MPa(3000psi) Stop
1.14 pressure display, delivery three shock proof pressure meter, three gas-operated shock proof pressure sensor:
25MPa(3625psi)×1 
40MPa(5800psi)×2
1.15 hydraulic pressure output interface, input interface NPT 1″14个、NPT1″1个,choose either inside or outside screw thread
2.1 appearance and weight of driller’s console 800(L)×450(W)×1800(H)、Weight:0.15t
2.2 Control function by pass control 1, pressure reducing valve control 1, three-position four-way turning valve 7
2.3 display function air source pressure 1,long distance liquid pressure 3, BOP switch position 7
2.4 air source pressure >0.6MPa~0.8 MPa(87~116psi)
2.5 control lag time less than 2 seconds
2.6 remote control pipe cable 23×4×50m,0.8Mpa(116psi),-20℃~50℃
3.1 appearance and weight of assistant drill controller 750mm(L)×450mm(W)×1280mm(H)
Weight:0.12t
3.2 control function BOP switch position 7
3.3 display function air source pressure 1, long distance liquid pressure 3
3.4 air source pressure >0.6MPa~0.8 MPa(87~116psi)
3.5 remote control pipe cable ≤2Sed
3.6 remote control pipe cable 19×4×50m,0.8Mpa(116psi),-20℃~50℃
Read 6276 times